American Journal of Electrical and Electronic Engineering. 2016, 4(3), 92-101
DOI: 10.12691/AJEEE-4-3-4
Original Research

Analytical Review of Power Flow Tracing in Deregulated Power System

P. K. Hota1, and A. P. Naik2

1Department of Electrical Engineering, Veer Surendra Sai University of Technology (VSSUT), Burla, India

2Department of Electrical Engineering, Bhadrak Institute of Engineering and Technology, Bhadrak, India

Pub. Date: July 02, 2016

Cite this paper

P. K. Hota and A. P. Naik. Analytical Review of Power Flow Tracing in Deregulated Power System. American Journal of Electrical and Electronic Engineering. 2016; 4(3):92-101. doi: 10.12691/AJEEE-4-3-4

Abstract

Electric Power starts flowing when there is a Source and Sink gets connected. Transmission corridor facilitates that power to flow. The problem arises in the analysis of individual power through a common transmission corridor of a larger system which is called power flow tracing. In the pre-deregulated system, due to the monopolistic nature of governance, the consumer was nothing to say about the tariff or choosing its service provider. But in the free-market or deregulated market system, the price to be charged must be based on fair and transparent manner. So analysis of individual customer’s power in a common supply corridor is a major contribution towards the fair and transparent analysis of price. Efficient power flow tracing would make it possible to charge the generators and/or consumers on the basis of actual transmission facility used. This paper deals with the detailed procedure for obtaining active and reactive power tracing for the actual active and reactive power transmitted through a common corridor between generators and loads. Initially, from the Newton-Raphson based load flows, the line flows are computed and then the multiplying factors of the lossy lines are calculated using proportional sharing method. Finally, based on the multiplying factors, the contributions of each line to concerned loads are obtained for both active and reactive power flow tracing. The method is used elaborately in a Six-bus system and subsequently applied to standard IEEE-14 and IEEE-30 Bus test systems and the results are presented.

Keywords

power flow tracing, proportional sharing method, deregulated power system, lossy line, multiplying factor

Copyright

Creative CommonsThis work is licensed under a Creative Commons Attribution 4.0 International License. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/

References

[1]  J.Yang, M.D. Anderson, “Tracing the flow of power in transmission networks for use-of-transmission-system changes and congestion management”, Proceedings of IEEE PES, Winter meeting, Vol.1, January 31-Feb 4, 1999, pp.399-405.
 
[2]  A.R. Shirani, H. Siahkali, “Traceable flow method in determination of congestion cost assignment in open access power system network”, Proceedings of IEEE PES, Transmission and Distribution Conference, Yokahama, Japan, October 2002, pp.734-738.
 
[3]  A.G. Exposito, J.M.R. Santos, T.G. Garcia, E.R. Velasco, “Fair allocation of transmission power losses”, IEEE Trans. on Power Syst., Vol.15, February-2000, pp.184-188.
 
[4]  G. Strbac, D. Kirschen, S. Ahmed, “Allocating transmission system usage on the basis of traceable contributions of generators and loads to flows”, IEEE Trans. on Power Syst., Vol.13, May-1998, pp.527-534.
 
[5]  D. Kirschen, G. Strbac, “Tracing active and reactive power between generators and loads using real and imaginary currents”, IEEE Trans. on Power Syst., Vol.14, November- 1999, pp.1312-1319.
 
[6]  A.J. Canejo, F.D. Galiana, I. Kockar, “Z-buss loss allocation”, IEEE Trans. on Power Syst., Vol.16, February-2001, pp.105-110.
 
[7]  A.M. Leite, J.G. Carvalho Costa, “Transmission loss allocation. Part-I: Single energy market”, IEEE Trans. on Power Syst., Vol.18, November-2003, pp.1389-1394.
 
[8]  A. Canejo, N. Alguacil, G.F. Ruiz,, “Allocation of the cost of transmission losses using a radial equivalent network”, IEEE Trans. on Power Syst., Vol.18, November-2003, pp.1353-1358.
 
[9]  A.J. Canejo, J.M. Arroyo, N. Alguacil, A.L. Guijarro, “Transmission loss allocation: a comparison of different practical algorithms”, IEEE Trans. on Power Syst., Vol.17, August-2002, pp.571-576.
 
[10]  G. Gross, S. Tao, “A physical-flow-based approach framework”, IEEE Trans. on Power Syst., Vol.15, No.2, May-2000, pp.631-637.
 
[11]  A.M. Leite, J.G. Carvalho Costa, “Transmission loss allocation. Part-II: Single energy market”, IEEE Trans. on Power Syst., Vol.18, November-2003, pp.1395-1401.
 
[12]  J.W. Bialek, S. Zeimianek, R. Wallace, “A methodology for allocating transmission losses due to cross-border trades”, IEEE Trans. on Power Syst., Vol.19, August-2004, pp.1255-1262.
 
[13]  S. Abdelkader, “Transmission loss allocation in a deregulated electrical energy market”, Electric Power Systems Research, Vol.76, 2006, pp.962-967.
 
[14]  Mohd. Herwan Sulaiman, Mohd. Wazir Mustafa, Hussain Shareef, Saiful Nizam Abd. Khalid, “An application artificial bee colony algorithm with least squares support vector machine for real and reactive power tracing in deregulated power system”, Electrical Power and Energy Systems, Vol.37, 2012, pp.67-77.
 
[15]  Hadi Saadat, “Power System Analysis”, Tata McGraw-Hill, New Delhi, 2002.